Ningbo Jiajie Electronics Co.,Ltd. is AC power cords manufacturer in China

PVC insulated Cables







































 
DIN VDE 0281 HD21
KTL K60227 CCC GB5023
CONDUCTOR INSULATION JACKET WIRE EXRADIUS
No.of
core
sectional
area(mm2)
Nom.
Thick
(mm)
Nom.
Thick
(mm)
LIM DOME(mm) LIM DOME
(mm)
300/300V VDE H03VVH2-F  60oC
KTL CCC  60227IEC52(RVV)
2

0.5

0.5

0.6

3.0*5.2

3.4*5.6

0.75

0.5

0.6

3.2*5.4

3.6*5.8

300/500V VDE H05VVH2-F  60oC
KTL CCC  60227IEC53(RVV)
2

0.75

0.6

0.8

3.8*6.3

4.2*6.7

1.0

0.6

0.8

4.0*6.7

4.4*7.1

300/300V VDE H03VV-F  60oC
KTL CCC  60227IEC52(RVV)
2

0.5

0.5

0.6

4.9

5.3

0.75

0.5

0.6

5.4

5.8

3

0.5

0.5

0.6

5.2

5.6

0.75

0.5

0.6

5.7

6.1

4

0.5

0.5

0.6

5.7

6.1

0.75

0.5

0.6

6.3

6.7

300/500V VDE H05VV-F  60oC
KTL CCC  60227IEC53(RVV)
2

0.75

0.6

0.8

6.2

6.6

1.0

0.6

0.9

6.6

7.0

1.5

0.7

0.8

7.6

8.0

2.5

0.8

1.0

9.2

9.6

4.0

0.8

1.1

11.1

11.5

3

0.75

0.6

0.8

6.6

7.0

1.0

0.6

0.8

7.0

7.4

1.5

0.7

0.9

8.3

8.7

2.5

0.8

1.1

9.9

10.3

4.0

0.8

1.2

12.0

12.4

4

0.75

0.6

0.8

7.4

7.7

1.0

0.6

0.9

8.5

8.9

1.5

0.7

1.0

9.3

9.7

2.5

0.8

1.1

11.5

11.9

4.0

0.8

1.2

13.2

13.6

5

0.75

0.6

0.9

8.3

8.7

1.0

0.6

0.9

8.7

9.1

1.5

0.7

1.1

10.3

10.7

2.5

0.8

1.2

12.8

13.2

4.0

0.8

1.4

14.8

15.2

 

 

 

CONDUCTOR INSULATION JACKET AMP
No.
of
core
AWG
size
sectional
area(mm2)
Nom.
Thick
(mm)
Nom.
Thick*
(mm)
Nom.
Thick
(mm)
Nom.
Diam
(mm)
SPT-1   SPT-1W
UL 62  300V UL/CSA  60--105oC
2 20 0.519 - - 0.76 2.8*5.1 7A
18 0.823 - - 0.76 3.0*5.6 10A
3 18 0.823 0.76 - - 3.0*8.2 10A
18 0.823 0.76 0.38 - 2.9*7.3 10A
NISPT-1
UL 62  300V UL/CSA  60--105oC
2 18 0.823 0.38 - 0.38 3.0*5.6 10A
3 18 0.823 0.38 - 0.38 3.0*8.2 10A
SPT-2   SPT-2W
UL 62  300V UL/CSA  60--105oC
2 18 0.823 1.14 - - 3.8*7.3 10A
16 1.31 1.14 - - 4.1*7.9 13A
3 18 0.823 1.14 - - 3.8*10.7 10A
18 0.823 - 0.38 1.14 3.7*8.7 13A
16 1.31 1.14 - - 4.1*11.6 13A
16 1.31 - 0.38 1.14 4.0*9.6 13A
NISPT-2
UL 62  300V UL/CSA  60--105oC
2 18 0.823 0.76 - 0.38 3.8*7.4 10A
16 1.31 0.76 - 0.38 4.1*8.0 13A
3 18 0.823 0.76 - 0.38 3.8*10.9 10A
16 1.31 0.76 - 0.38 4.1*11.8 13A
SPT-3
UL 62  300V UL/CSA  60--105oC
2 18 0.823 - - 1.52 4.5*8.8 10A
16 1.31 - - 1.52 4.8*9.4 13A
14 2.08 - - 2.03 6.2*11.2 15A
12 3.31 - - 2.41 7.5*12.9 20A
10 5.26 - - 2.79 8.9*15.0 30A
3 18 0.823 0.38 - 1.52 4.5*10.2 10A
16 1.31 0.38 - 1.52 4.8*11.1 13A
14 2.08 0.38 - 2.03 6.2*13.3 15A
12 3.31 0.38 - 2.41 7.4*15.5 20A
10 5.26 0.38 - 2.79 8.8*18.2 30A
SVT  SVTO
UL 62  300V UL/CSA  60--105oC
CONDUCTOR INSULATION JACKET AMP
No.
of
core
AWG
size
sectional
area(mm2)
Nom.
Thick
(mm)
Nom.
Diam
(mm)
Nom.
Thick
(mm)
Nom.
Diam
(mm)
2 18 0.823 0.38 2.05 0.76 5.9 10A
17 1.03 0.38 2.15 0.76 6.3 12A
16 1.31 0.38 2.3 0.76 6.5 13A
3 18 0.823 0.38 2.05 0.76 6.3 10A
17 1.03 0.38 2.15 0.76 6.7 12A
16 1.31 0.38 2.30 0.76 6.8 13A
SJT  SJTW  SJTO  SJTOW  SJTOOW
UL 62  300V UL/CSA  60--105oC
2 18 0.823 0.76 2.80 0.76 7.25 10A
16 1.31 0.76 3.10 0.76 7.80 13A
14 2.08 0.76 3.50 0.76 8.70 15A
12 3.31 0.76 4.00 1.14 1.30 20A
10 5.26 1.14 5.40 1.52 14.10 30A
3 18 0.823 0.76 2.80 0.76 7.80 10A
16 1.31 0.76 3.10 0.76 8.60 13A
14 2.08 0.76 3.50 0.76 9.25 15A
12 3.31 0.76 4.00 1.14 11.00 20A
10 5.26 1.14 5.40 1.52 14.80 30A
4 18 0.823 0.76 2.80 0.76 8.45 10A
16 1.31 0.76 3.10 0.76 9.20 13A
14 2.08 0.76 3.50 0.76 10.20 15A
12 3.31 0.76 4.00 1.14 12.10 20A
10 5.26 1.14 5.40 1.52 16.40 30A
5 18 0.823 0.76 2.80 0.76 9.2 10A
16 1.31 0.76 3.10 0.76 10.4 13A